Malfunction Cause Remedy
Without power Fuse faulty,
not switched ON
Short circuit
New fuse, switch ON
mains switch, check lead
with a voltage detector
Check connections
Does not switch ON Twilight setting in
night-time mode during
daytime operation
Bulb faulty
Power switch OFF
Fuse faulty
Detection zone not targeted
Adjust setting
Replace light bulbs
Switch ON
New fuse, check
connection if necessary
Re-adjust
Does not switch OFF Continued movement in
the detection zone
Light is in detection zone
and keeps switching ON
as a result of temperature
change
Check zone and re-adjust
or shroud if necessary
Change zone, or apply
shroud
Keeps switching ON/OFF Lamp being operated
in the detection zone
Animals moving in the
detection zone
Adjust zone, shroud or
increase distance
Adjust zone, or apply
shroud
Switches ON when it
should not
Wind moves trees and
bushes in the detection
zone
Cars in the street are
being detected
Sudden change in temp-
erature due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
Adjust zone or
apply shroud
Adjust zone or
apply shroud
Adjust zone, change
installation site
LED flashes rapidly Overload protection
activated
Switch OFF unit and
switch ON again after
cooling down
Troubleshooting
14
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to
sensor mode.
Manual override function
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The lamp is
set to stay on for 4 hours (red LED lights up
behind the lens). Then it returns automatically
to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes
out or switches over to sensor mode.
If a mains switch is installed in the mains supply
lead, the light is capable of the following func-
tions in addition to the simple ON/OFF function:
Important: The switch should be operated
several times in rapid succession.
Technical specifications
Dimensions (H x Ø): 82 x 51 mm
Output: max. 1000 W (filament bulbs)*
max. 5 AX (fluorescent lamps)*
Switching capacity: 50 – 240 V~ / 5 A
Connection: 230 – 240 V/50 Hz
Angle of coverage: 360° with 180° angle of aperture
Reach: 8 m max. all round
Sensor system: 10 detection zones, 720 switching zones
Time setting: 5 sec. – 20 min.
Twilight setting: 2 – 2000 lux
Manual override: 4 hrs. selectable
Enclosure (top/bottom): IP 20
Temperature range: -20 °C to +50 °C
*VDE tested
Reach setting / adjustment
With an assumed mounting height of 2.5 m,
the maximum reach of the sensor is 8 m. The
detection zone can be optimally adjusted ac-
cording to needs. The shroud provided can be
used for masking out any number of lens seg-
ments to shorten reach as required. This pre-
vents the light from being activated uninten-
tionally, e.g. by cars, passers-by etc. and
allows you to target danger spots. The shroud
can be separated along the pre-grooved div-
isions in the vertical and horizontal directions
and applied to the lens.